Mechanical and Environmental Specifications
- Size: 3.67W x 9.5H x 5.98D
- Operating Temperature: +32°F to +122°F
(0°C to +50°C)
- Storage Temperature: -40°F to +167°F
(-40°C to +75°C)
- Humidity: 95% maximum, non-condensing
- Altitude: 10,000 feet (3,048 meters) max.
- Weight: 7.75 lbs. (3.52 kg)
Electrical Specifications
- AC Input Range: 90 to 132 VAC, 50/60 Hz
- AC Current: 7 amperes
- Fuse Rating: 250 volts, 8 amperes
- Drive Power Dissipation (Worst Case): 50 watts
Isolated Digital I/O
- 12V DC Internal I/O Power: 11.5 to 14V DC @ 100mA
- or User Supplied I/O Power: 5-24V DC
Inputs (IN1 - IN8):
- Sink Mode: (+Vopto = 12V DC)
- On State Voltage Range (Vin): 0V to +6V DC
- Input Current (Vin = 0V): -6mA
Source mode:
- On State Voltage Range (Vin): 4.5V to 24V
- Input Current (Vin = 12V DC): 6mA
Response Time (sink or source):
- Opto Turn On Delay: 10uS typical
- Opto Turn Off Delay: 75uS typical
Programmable Outputs (OUT1-OUT4):
Sink Mode:
- Continuous Current Rating per Output: 250mA max.
- Maximum Collector Voltage: 25V max.
- On State Voltage @ 250mA: 1.5V max.
Non-Isolated I/O (or BCD Interface):
IN9 - IN 16: These inputs may be used with open
collector outputs without an external supply by connecting
the output device common (ground) to signal ground on
the unit, and the open collector to the input pin. An
internal pullup resistor to +5V DC is provided.
OUT5 - OUT8: These are open-collector, sink only
TTL outputs, and are NOT isolated from the unit's +5V
logic supply. Proper care must be taken to ensure noise is
not injected onto these signals. The user's I/O supply must
be referenced to GND on the controller.
- Active Output Voltage: 0.6V max. @ 20mA
- Permissible Output Current: 20mA
- Permissible Output Voltage: 24V DC
Serial Communications:
- Port 1: Configurable for RS-232C or RS-485 four
wire communications via a switch. Port 1 is designated as
the HOST communications port and can be used to
daisy chain up to 32 units in RS485 mode.
- Port 2: Serial port 2 is used for differential RS485
four wire USER communications.
Encoder Connections:
Encoder connections provide power and inputs for a
digital encoder interface to indicate motor position to
the controller.
Encoder +5V DC
- Power Supply Output: +5V DC
(±5%) @ 100mA current.
- Encoder Signal Inputs: TTL level
Single-ended or differential; channels A and B in phase
quadrature.
- Input Current A+, A-, B+, B-, Z+, Z-:
±5mA min.
Analog Input:
- Voltage Range: 0-10V referenced to GND
- Resolution: 10 bits or 9.77mV
- Absolute Accuracy: ±0.3V worst case
- Sample Rate: 500 Hz min.
- Bandwidth: 100 Hz max.
|